Cleanroom Hoods
Laminar Flow Hoods
Cleanroom laminar flow hoods offer particle-free work areas designed to increase productivity. Laminar air flow hoods protect the product or process from contaminants introduced by many sources such as personnel, equipment or from the product itself. Our standard Laminar Flow Hoods and Table Top Laminar Flow Benches are a cost-effective solution for isolating critical applications.
Download Our Laminar Flow Hood and Table Top Laminar Flow Benches Brochures for More Details
ISO 5 Compounding Hoods
ISO 5 compounding hoods for laboratory applications can provide either horizontal or vertical air streams. Make sure to select an ISO 5 compounding hood that provides adequate space for your process. A congested cleanroom laminar hood can also obstruct the air flow and increase particle accumulation.
Compounding hood options include:
Type: Tabletop (TS series), Console Slimline (CS series), Console (C series)
Material: Woodboard and plastic laminate, epoxy painted cold rolled steel, 304 stainless steel, polypropylene
Filter Area Size: Options ranging from 36”-96” width and 24”-36” height
View our Horizontal Work Station Selection form.
Horizontal and Vertical Laminar Flow Hood Options
Vertical Laminar Flow Hoods are recommended for applications where the process generates vapors, solvents, chemicals or other fine powders. In some cases where noxious fumes are being used, a vertical laminar flow hood should be utilized. Vertical laminar flow hoods may be floor or table top mounted depending on the available space. If vibration is a concern, a horizontal table top laminar flow hood unit would not be suitable.
Class II Biological Safety Cabinet Hoods
Probably The World's Most Advanced Energy Efficient, Quiet, and Compact BioSafety Cabinet
The Airstream® Class II Biological Safety Cabinet is an effective solution in providing operator, product and environmental protection within laboratories and industrial facilities. With the presence of its DC ECM blower, this is the most energy efficient Class II BioSafety Cabinet in the world with 70% energy savings compared to an AC motor. It also features stable and self-compensating airflow, despite building voltage fluctuations & filter loading. Its large performance envelope in an open declaration of possible safe operating airflow values. Certified EN 12469, Esco Airstream® Class II Biological Safety Cabinet also has antimicrobial coating on all its external and internal painted surfaces.
Download Our Class II Biological Safety Hoods Brochure for More Details
Fume Exhaust Hoods
We specialize in Polypropylene Fume Hood Exhaust units fabricated from white polypropylene, an extremely durable and non-corrosive thermoplastic. The material is highly resistant to most acids, solvents and other liquids. Units are made to order in five basic sizes. The basic console cleanroom fume hood requires a remote exhaust system.
Each cleanroom hood unit consists of:
White polypropylene structure with a sliding adjustable clear acrylic sas
Internal fluorescent lighting
Front panel for controls
A solid reinforced work surface with front lip
Removable rear baffles for cleaning
Hinged vented doors for storage below the work surface.
Our Constant Volume Bypass Fume Hoods are also available with vertical sliding counterbalanced face shields.
Download Our Fume Hood Brochure for More Details
Construction Solvent Hoods
Sterile hoods are fabricated with all internal plumbing, electrical and instrumentation complete as per customer requirements.
16 ga. 304 type stainless steel with a # 4 polish finish and reinforced table top.
Adjustable rear wall baffles for exhaust air.
Reinforced work surface for heavy loads.
Vented storage cabinet. ,/-0.5” static pressure drop across hood.
Mechanical leg leveling.
Rear exhaust plenum terminates at 10” dia.
Includes collar(s).
Angled sliding face shield with 12” opening at face.
6’-8’ hood shield in 2 sections with center support guide.
Also available in Epoxy painted steel, Polypropylene and 316L Stainless steel as required.
Click here to view our Cleanroom Fume Hood selection chart.
Wet Process Fume Exhaust Hood
We offer the WPS Series Wet Process Fume Exhaust Hood units that are designed as free-standing with vented base cabinets. It is designed for use in semiconductor research and manufacturing where process tanks, rinsers, heated baths require large sophisticated control modules. The nitrogen purged upper head case compartment located above the work surface is designed for these process equipment control modules to keep them at eye level within easy reach of the operator. By employing retractable clear PVC safety shields, efficient capture velocities can be maintained at significantly lower cfm. These cleanroom hood units operate with an exhaust blower (by others) to provide a means of removal of toxic fumes and odors. Adjustable baffles on the rear wall allow for proper balance of fumes through the cabinet. Many options are available for this cleanroom exhaust hood such as heated baths, dump rinsers, ultrasonic baths, sinks, gooseneck faucets, Di Spray Guns, Nitrogen Guns, etc.
Please contact CleanAir Solutions to request a no-obligation quote on any of our cleanroom laminar flow hoods, exhaust hoods, ISO 5 compounding hoods and more.
Get in touch.
If you have questions about our vertical flow hoods and other cleanroom hood products, please fill out the following form. You will be promptly contacted by a qualified cleanroom specialist.