Fan Filter Unit Accessories

Filter Accessories

 

When selecting the proper air filter for your cleanroom environment, it’s equally important to select the proper accessories. The right set of fan filter unit accessories support the specific functions of your filtration system. CleanAir Solutions offers a variety of cleanroom air filter accessories to choose from including final filters, ceiling collars, diffuser grilles, pilot lights, powder cords, speed controllers and sheet rock adaptors for installation into drywall or plaster ceilings.

Technical drawing of a cleanroom sheet rock adaptor

Sheet Rock Adaptors

Sheet Rock AdaptersFor Independent Support of SAM Filter Units in Solid Cleanroom Ceilings. These fan filter accessories are fabricated from white powder-coated steel or stainless steel and supplied with a factory-applied gasket.

Sheet Rock Adaptor Ordering Information

Ordering Information Table
Part No. Description Ceiling Opening Required
19993 2 x 2 White Sheet Rock Adaptor Min. 24-1/8 x 24-1/8
Max. 24-1/2 x 24-1/2
19994 2 x 4 White Sheet Rock Adaptor Min. 24-1/8 x 48-1/8
Max. 24-1/2 x 48-1/2
19995 2 x 4 Stainless Steel Sheet Rock Adaptor Min. 24-1/8 x 48-1/8
Max. 24-1/2 x 48-1/2
19996 2 x 2 Stainless Steel Sheet Rock Adaptor Min. 24-1/8 x 24-1/8
Max. 24-1/2 x 24-1/2
 
Technical drawing of a gasket-style cleanroom NCR HEPA filter

Ceiling Collars

Structural Support Frame For Independently Suspending SAM Filter Units in Solid Ceilings. Contact CleanAir Solutions for custom sizes.

Anodized Aluminum cleanroom ceiling collars with a factory applied gasket include four (4) Turnbuckles & an RH/LH Threaded Rod. Contractors are responsible for suspending the turnbuckle from the building structure.

Ordering Information
Part No. Ceiling Collar Description Ceiling Opening Required
19990 2 x 2 Anodized Aluminum Min. 25-1/4 x 25-1/4
Max. 25-3/4 x 25-3/4
19991 2 x 4 Anodized Aluminum Min. 25-1/4 x 49-1/4
Max. 25-3/4 x 49-3/4
19992 2 x 6 Anodized Aluminum Min. 25-1/4 x 73-1/4
Max. 25-3/4 x 73-3/4
 
 

Final Filters

NCR HEPA filters come with an option for a centerboard with Test Port. This feature allows for an aerosol challenge to be sampled on the upstream side of the air filter from room-side.

Final filters can be upgraded to ULPA high efficiency air filters rated at 99.9995% efficient @ 0.12 microns. These cleanroom air filters are typically used for applications of ISO Class 4 or better. ULPA filters are available in both our NCR and GS (gel seal) type construction.

 
Final Filter test port.jpg
Technical drawing of a cleanroom NCR HEPA filter

Order Replacement Filters

Replacement Filters
Code Replacement Filter Description
302070 2x2 NCR Style HEPA Filter, 99.99% eff. @ 0.3 micron
302071 2x2 NCR Style ULPA Filter, 99.9995% eff. @ 0.12 micron
302013 2x3 NCR Style HEPA Filter, 99.99% eff. @ 0.3 micron
302015 2x3 NCR Style ULPA Filter, 99.9995% eff. @ 0.12 micron
302090 2x4 NCR Style HEPA Filter, 99.99% eff. @ 0.3 micron
302100 2x4 NCR Style ULPA Filter, 99.9995% eff. @ 0.12 micron
302190 Prefilter 20” x 20” x 1”, 30% ASHRAE efficient, pleated type
 
Technical drawing of a cleanroom grille with a perforated screen

Perforated Grilles

Perforated diffuser grilles are valuable cleanroom filter accessories for sensitive areas where direct airflow can be damaging to your process. These grilles can be added to any cleanroom air filter model and come in both anodized aluminum, painted aluminum and stainless steel finishes.

Grilles 1/8” Round Perforated
Model No. Grilles 1/8" Round Perforated (40% Open Area) Size
19506 GS Anodized Aluminum Grille w/Anodized Aluminum Frame 2 x 2
19507 GS Anodized Aluminum Grille w/Anodized Aluminum Frame 2 x 4
19508 GS White Painted w/White Painted Frame 2 x 2
19509 GS White Painted w/White Painted Frame 2 x 4
19511 GS Stainless Steel Rd Grille w/Anodized Aluminum Frame 2 x 4
19512 GS Stainless Steel Rd Grille w/Anodized Aluminum Frame 2 x 2
19514 GS Stainless Steel Perf Grille w/Stainless Steel Frame 2 x 4
19525 GS Stainless Steel Perf Grille w/Stainless Steel Frame 2 x 2
Technical drawing of a cleanroom grille
 

Knife edge units are designed to be installed inside our Gel Seal style T-bar cleanroom ceiling system. Please consult with a CleanAir Solutions specialist about information on our SAM air filtration units with knife edge.

 
 
Technical drawing of a cleanroom “knife edge unit” for air filtration systems

Radial Diffuser Grilles

These fan filter grilles provide a greater diffuser range for large cleanroom spaces that require a lot of coverage.

Radial Diffuser Grille
Model No. Grille Description Size
19300 4 Way, Anodized Aluminum 2x2
19301 4 Way, Anodized Aluminum 2x4
19302 4 Way, Anodized Aluminum 2x6
Technical drawing of a cleanroom speed controller

Roomside Speed Controller

Roomside Variable Speed Control
Roomside Variable Speed Control Styles
GS Style Unit 110V, 60hz
GS Style Unit 208-230V, 50/60hz
GS Style Unit 277V, 60hz
 
Technical drawing of a cleanroom downstream gasket

Downstream Gasket

This cleanroom air filtration accessory offers downstream gasket on the bottom edge of our SAM fan filter units.

Downstream Gasket Orders

Downstream Gasket
Model No. Description
603322 Gasket on downstream edge of SAM Unit
 
Technical drawing showing the components of a cleanroom fan filter unit

Static Control Package for GS Fan Filter Units

The static pulse box controller is pre-wired and installed in our 2 x 4 GS fan filter units. Please specify voltage requirements in your model selection below.

Static Control Package for GS Units

(Static Pulse Box Controller is prewired and installed in 4ft. GS Unit)

Static Control Package
Model No. Description
19754 115V, 60hz, 2’ Models
19755 208-230V, 50/60Hz, 2’ Models
19750 115V, 60hz, 4’ Models
19751 208-230V, 50/60Hz, 4’ Models
19752 115V, 60hz, 6’ Models
19753 208-230V, 50/60Hz, 6’ Models
 

Get in touch for more FFU accessory information.

We understand you may have questions about our FFU accessories, plus the other products and services offered by CleanAir Solutions. Please fill out the following form and you will be promptly contacted by a qualified member of our staff.